Connect Lidar to the Pixwahk by 6 pin connector to the I2C port by the 3 pin connector .
Connect the Pixhawk to the laptop and go to vehicle setup -> parameters and set the following parameters:-
- RNGFND1_TYPE = 3 “LidarLite-I2c”
- RNGFND1_MAX_CM = 3500 (the maximum range the lidar can accurately report in cm)
- RNGFND1_MIN_CM = 20 (the mininum range the lidar can accurately report in cm)
To check if the lidar is working back to home page and go to Analyze tools ->Mavlink inspector -> DISTANCE_SENSOR and if the frequency is non-zero and the current distance is changing upon moving the lidar means the lidar is working properly.