Hi @Bin-Ma , in your step Best, |
Hi @PengNi , I'm also trying to detect 6mA and 5mC in bacterial sample but only find the model model.GATC.R9_2D.tem.puc19.bn17.sn360/bn_17.sn_360.epoch_5.ckpt in the google drive that are supposed to using on version <0.16. For Deepsignal2, there's only one human CG motif. Thanks, |
@wenluo711 , if you want to detect 6mA and 5mC in bacterial samples, I suggest using Remora/mCaller/nanodisco. Right now deepsignal/deepsignal2 only performs well in 5mCpG detection. Best, |
@PengNi Thanks for your reply. I finished the 6mA detection using Deepsignal now. However, the correlation against other software (DeepMod, mCaller) was low. I don't know how to set the cutoff value of Deepsignal. Best, |
Hi, @PengNi I tried the Deepsignal for 6mA detection and all the position is matched with the 5mC modification on the reference sequence. I don't know what happened about my command. Looking forward to your reply.
deepsignal call_mods --motifs GATC --input_path ./barcode01/deepsignal_feature.tsv --is_gpu yes --model_path ~/software/deepsignal/model.GATC.R9_2D.tem.puc19.bn17.sn360/bn_17.sn_360.epoch_5.ckpt --result_file ./barcode01/deepsignal_prob_A.tsv