In OCLBP.cpp:115, the computed filter center index is 5, for a 3x3 filter, instead of 4. Probably a typo from the translation of the Matlab code (Matlab indexes start at 1).
The text was updated successfully, but these errors were encountered:
In OCLBP.cpp:115, the computed filter center index is 5, for a 3x3 filter, instead of 4. Probably a typo from the translation of the Matlab code (Matlab indexes start at 1).