-
Notifications
You must be signed in to change notification settings - Fork 6
/
bom.ini
114 lines (107 loc) · 4.16 KB
/
bom.ini
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
[BOM_OPTIONS]
; General BoM options here
; If 'ignore_dnf' option is set to 1, rows that are not to be fitted on the PCB will not be written to the BoM file
ignore_dnf = 1
; If 'html_generate_dnf' option is set to 1, also generate a list of components not fitted on the PCB (HTML only)
html_generate_dnf = 1
; If 'use_alt' option is set to 1, grouped references will be printed in the alternate compressed style eg: R1-R7,R18
use_alt = 0
; If 'number_rows' option is set to 1, each row in the BoM will be prepended with an incrementing row number
number_rows = 1
; If 'group_connectors' option is set to 1, connectors with the same footprints will be grouped together, independent of the name of the connector
group_connectors = 1
; If 'test_regex' option is set to 1, each component group will be tested against a number of regular-expressions (specified, per column, below). If any matches are found, the row is ignored in the output file
test_regex = 1
; If 'merge_blank_fields' option is set to 1, component groups with blank fields will be merged into the most compatible group, where possible
merge_blank_fields = 1
; Specify output file name format, %O is the defined output name, %v is the version, %V is the variant name which will be ammended according to 'variant_file_name_format'.
; output_file_name = %O_bom_%v%V
output_file_name = %O_bom
; Specify the variant file name format, this is a unique field as the variant is not always used/specified. When it is unused you will want to strip all of this.
variant_file_name_format = _(%V)
; Field name used to determine if a particular part is to be fitted
fit_field = Population
; Complex variant processing (disabled by default)
complex_variant = False
; Character used to separate reference designators in output
ref_separator = ' '
; Make a backup of the bom before generating the new one, using the following template
make_backup = %O.tmp
; Default number of boards to produce if none given on CLI with -n
number_boards = 1
; Default PCB variant if none given on CLI with -r
board_variant = [u'default']
; Whether to hide headers from output file
hide_headers = False
; Whether to hide PCB info from output file
hide_pcb_info = False
; Interpret as a Digikey P/N and link the following field
digikey_link = False
[IGNORE_COLUMNS]
; Any column heading that appears here will be excluded from the Generated BoM
; Titles are case-insensitive
Part Lib
Footprint Lib
Description
Part
Part Lib
Sheetpath
Datasheet
[COLUMN_ORDER]
; Columns will apear in the order they are listed here
; Titles are case-insensitive
Quantity Per PCB
References
Value
MPN1
MPN2
Build Quantity
Footprint
Footprint Lib
Population
[GROUP_FIELDS]
; List of fields used for sorting individual components into groups
; Components which match (comparing *all* fields) will be grouped together
; Field names are case-insensitive
Part
Part Lib
; Value
MPN1
MPN2
Footprint
Footprint Lib
[COMPONENT_ALIASES]
; A series of values which are considered to be equivalent for the part name
; Each line represents a list of equivalent component name values separated by white space
; e.g. 'c c_small cap' will ensure the equivalent capacitor symbols can be grouped together
; Aliases are case-insensitive
c c_small cap capacitor
r r_small res resistor
sw switch
l l_small inductor
zener zenersmall
d diode d_small
[JOIN]
; A list of rules to join the content of fields
; Each line is a rule, the first name is the field that will receive the data
; from the other fields
; Use tab (ASCII 9) as separator
; Field names are case sensitive
[REGEX_INCLUDE]
; A series of regular expressions used to include parts in the BoM
; If there are any regex defined here, only components that match against ANY of them will be included in the BOM
; Column names are case-insensitive
; Format is: "[ColumName] [Regex]" (white-space separated)
[REGEX_EXCLUDE]
; A series of regular expressions used to exclude parts from the BoM
; If a component matches ANY of these, it will be excluded from the BoM
; Column names are case-insensitive
; Format is: "[ColumName] [Regex]" (white-space separated)
References ^TP[0-9]*
References ^FID
Part mount.*hole
Part solder.*bridge
Part test.*point
Footprint test.*point
Footprint mount.*hole
Footprint fiducial