You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
dslog.txt Describe the bug
When running Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SingleFamilyHouse.Radiator the simulation fails with the following error message:
... Error message from dymosim
At time T = 1.260000e+04 and stepsize
H = 1.370330e-10 the code had repeated error test failures
on the last attempted step. A singularity in the solution may be
present. (For DAEs: Provide initial values of X and of XD which
are consistent). Integration will be terminated.
The simulation analysis indicates that there is a problem with the radiative heat port in Buildings.ThermalZones.EnergyPlus_9_6_0.ThermalZone. When the radiative heat port of the radiator is connected with the heat port of the air volume instead of the radiative heat port of the zone, the simulation terminates successfully.
dslog.txt
Describe the bug
When running Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SingleFamilyHouse.Radiator the simulation fails with the following error message:
The simulation analysis indicates that there is a problem with the radiative heat port in Buildings.ThermalZones.EnergyPlus_9_6_0.ThermalZone. When the radiative heat port of the radiator is connected with the heat port of the air volume instead of the radiative heat port of the zone, the simulation terminates successfully.
To Reproduce
Steps to reproduce the behavior:
Expected behavior
The simulation of the example should terminate successfully.
Screenshots
Version