Devices from Leaf device family provide a 48-bit counter running at 48 MHz for hardware time stamps. This counter will overflow after 3:15:28.124 hours.
Mhydra devices
Devices from Mhydra device family provide a 64-bit counter running at 80 MHz which will overflow after 2668 days and 19:11:40.921 hours (approx. 7.3 years).
The text was updated successfully, but these errors were encountered:
Leaf devices
Devices from Leaf device family provide a 48-bit counter running at 48 MHz for hardware time stamps. This counter will overflow after 3:15:28.124 hours.
Mhydra devices
Devices from Mhydra device family provide a 64-bit counter running at 80 MHz which will overflow after 2668 days and 19:11:40.921 hours (approx. 7.3 years).