I downloaded and built v0.3.1 and seem to be stuck with an interface timeout error. I get a similar error with the can_moni and can_test programs. Below is the result of kvl_test TEST INFO which i saw was the most informative from other posts/issues.
Any help appreciated.
dtravis@Dexter-MacBook-Pro KvaserCAN-Library % ./Trial/kvl_test TEST INFO
>>> CAN API V3 for Kvaser CAN Interfaces, Version 0.3.1 (0xaaa925f)
>>> myDriver.GetProperty(CANPROP_GET_SPEC): value = 3.0
>>> myDriver.GetProperty(CANPROP_GET_VERSION): value = 0.3
>>> myDriver.GetProperty(CANPROP_GET_PATCH_NO): value = 1
>>> myDriver.GetProperty(CANPROP_GET_BUILD_NO): value = aaa925f
>>> myDriver.GetProperty(CANPROP_GET_LIBRARY_ID): value = 600
>>> myDriver.GetProperty(CANPROP_GET_LIBRARY_DLLNAME): value = 'libUVCANKVL.dylib'
>>> myDriver.GetProperty(CANPROP_GET_LIBRARY_VENDOR): value = 'UV Software, Berlin'
Loading the MacCAN driver...
- One device added at location 02140000
- Device #0: Kvaser Leaf Light v2
- Properties: vendor = bfd, product = 120, release = 0001, speed = 2
- Run loop started so notifications will be received
>>> CCanAPI::ProbeChannel(0): state = available
+++ Sorry, device #1 is not available
>>> CCanAPI::ProbeChannel(1): state = not available
+++ Sorry, device #2 is not available
>>> CCanAPI::ProbeChannel(2): state = not available
+++ Sorry, device #3 is not available
>>> CCanAPI::ProbeChannel(3): state = not available
+++ Sorry, device #4 is not available
>>> CCanAPI::ProbeChannel(4): state = not available
+++ Sorry, device #5 is not available
>>> CCanAPI::ProbeChannel(5): state = not available
+++ Sorry, device #6 is not available
>>> CCanAPI::ProbeChannel(6): state = not available
+++ Sorry, device #7 is not available
>>> CCanAPI::ProbeChannel(7): state = not available
+ Device #0: asynchronous event source added to run loop
- Message pipe of size 512 bytes
- Message queue for 65536 elements of size 88 bytes
- Double buffer each of size 512 bytes for endpoint #1
Initializing Kvaser Leaf Light v2 driver...
>>> Kvaser Leaf Light v2 (device #0): stop chip (go bus OFF)
>>> Kvaser Leaf Light v2 (device #0): set driver mode NORMAL
>>> Kvaser Leaf Light v2 (device #0): trigger chip state event
+++ Kvaser Leaf Light v2 (device #0): card information could not be read (-50)
+++ Sorry, device #0 is not opened or not available
+++ error: myDriver.InitializeChannel(0) returned -50
Cheers!
dtravis@Dexter-MacBook-Pro KvaserCAN-Library % ./Binaries/can_moni 'Kvaser CAN Channel 0' --baudrate=500 --mode=2.0 -v
CAN Monitor for Kvaser CAN Interfaces, Version 0.3.1 (0xaaa925f)
Copyright (c) 2007,2020-2022 by Uwe Vogt, UV Software, Berlin
This program comes with ABSOLUTELY NO WARRANTY!
This is free software, and you are welcome to redistribute it
under certain conditions; type `--version' for details.
Op.-mode=CAN2.0 (op_mode=00h)
[email protected]% (f_clock=8000000,nom_brp=1,nom_tseg1=13,nom_tseg2=2,nom_sjw=1,nom_sam=0)
Hardware=Kvaser CAN Channel 0...FAILED!
+++ error: CAN Controller could not be initialized (-50)
Copyright (c) 2007,2020-2022 by Uwe Vogt, UV Software, Berlin
The text was updated successfully, but these errors were encountered:
Update. It appears this may be related to the particular Kvaser device. When i tried with a newer Kvaser of the same model it functions correctly with the both kvl_test and can_moni.
Is there possibly a minimum FW version we need from the Kvaser?