conversion factor corrected
Browse files Browse the repository at this point in the history
  • Loading branch information
mkgeiger committed Mar 7, 2019
1 parent 5c83052 commit 2e08d08
Show file tree
Hide file tree
Showing 2 changed files with 5 additions and 5 deletions.
8 changes: 4 additions & 4 deletions GeigerCounter/GeigerCounter.ino
Original file line number Diff line number Diff line change
Expand Up @@ -16,9 +16,9 @@
#define AP_NAME "geiger_counter"
#define AP_TIMEOUT 60

// Geiger Mueller tube parameterization (see datasheet of SBM-20)
// gamma sensivity for Radium224: 29cps = 1740cpm ≙ 1mR/h = 10μS/h -> 1cpm ≙ 0.0057μS/h
#define SBM20_FACTOR ((double)0.0057)
// Geiger Mueller tube parameterization (see manufacturer of radiation kits: http://www.libelium.com/wireless_sensor_networks_to_control_radiation_levels_geiger_counters/)
// gamma sensivity: 60cps = 3600cpm ≙ 1mR/h = 10μS/h -> 1cpm ≙ 0.00277μS/h
#define SBM20_FACTOR ((double)0.00277)
#define NBR_GMTUBES 2
#define TUBE_FACTOR (SBM20_FACTOR / (double)NBR_GMTUBES)

Expand Down Expand Up @@ -552,7 +552,7 @@ void loop()
// setup the google chart options here
client.println(" var options = {");
client.println(" width: 700, height: 600,");
if (lastcSvTmp < 1.0)
if (lastcSvTmp < 1.0)
{
client.println(" min: 0, max: 1,");
client.println(" greenFrom: 0, greenTo: .25,");
Expand Down
2 changes: 1 addition & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -66,7 +66,7 @@ First install the [Arduino IDE](https://www.arduino.cc/en/main/software). Under

### GM-tube parameterization

The GM-tube conversion factor can be adapted in the source code when other GM-tubes are used. In the datasheet of the SBM-20 tube we find following: Gamma Sensivity Ra226 = 29 cps/mR/h. In other words: 29 cps are equivalent to 1 mR/h. Or 1740 cpm are equivalent to 10μS/h. Or 1 cpm is equivalent to 0.0057 μS/h. This conversion factor has to be divided by the number of used GM-tubes.
The GM-tube conversion factor can be adapted in the source code when other GM-tubes are used. At [Libellum](http://www.libelium.com/wireless_sensor_networks_to_control_radiation_levels_geiger_counters/) (the company that manufactures radiation kits) declares for the SBM-20 tube a convertion factor of 0.00277, which is equivalent to a gamma sensivity of 60 cps/mR/h. In other words: 60 cps are equivalent to 1 mR/h. Or 3600 cpm are equivalent to 10μS/h. Or 1 cpm is equivalent to 0.00277 μS/h. This conversion factor has to be divided by the number of used GM-tubes.