Do you have "Charge efficiency factor %" set to 99% ? That will have the effect of subtracting 1% from the 100% on reset. |
yes charge efficency was at 99% interesting, if the shunt should reset to 100% at full charge it reset to the Charge efficiency factor % value this was not the case with older firmware |
The whole SoC calculation is different in this version - the previous one was incorrect. It doesn't set to the charge efficiency factor % directly. The SoC is calculated on the amps in vs out, and the factor % is applied to the "in" value to determine the SoC. |
what is the charge efficency factor for, if it has to be set to 100% ? make no sence for me, ok i will set it to 100%... |
When you charge any battery, some energy is lost - thats the efficiency. Lithium cells are very good - hence 99%+ - lead acid less so, probably 90% |
i undestand, but in this case if i set 99,5% efficency it wil never reset to 100%... but it has to |
Ok, set it to 100% then. |
Hi @stuartpittaway When discharging, voltage drops for example to 53,14V, SoC changes to 72,34%. Maybe there's something, which I don't underestand. |
Voltage has nothing to do with the SoC calculation ! Its only used to identify when 100% fully charged has been reached - 58.8V in your case. After that, its down to amp-hour counting. You can't apply a linear voltage drop calc to Lithium cells, they don't have a linear charge curve. |
any news on this issue? |
The state of charge does indeed reset to 100% when the conditions are met, however from that 100% value the charge efficiency is removed, typically this introduces the 99% value you see. |
hmm, so i have to live with the 99% on full? victron shunt does it right, it reset to 100% but still a "charge efficency" can be set seperatly |
There has been a code change submitted by another use to change the behaviour so that the soc goes to 100%, but that's not been incorporated into the main code base. |
could you please integrate it in the external shunt firmware, if its not to much work? |
This is related to issue stuartpittaway/diyBMSv4ESP32#232 |
the shunt reset to 99% not to 100% looks like a bug.
[Release-2023-01-25-12-26]
The text was updated successfully, but these errors were encountered: