forked from robinson/gos7
-
Notifications
You must be signed in to change notification settings - Fork 0
/
api.go
84 lines (81 loc) · 3.31 KB
/
api.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
package gos7
// Copyright 2018 Trung Hieu Le. All rights reserved.
// This software may be modified and distributed under the terms
// of the BSD license. See the LICENSE file for details.
import (
"time"
)
//Client interface s7 client
type Client interface {
/***************start API AG (Automatisationsgerät)***************/
//Read data blocks from PLC
AGReadDB(dbNumber int, start int, size int, buffer []byte) (err error)
//write data blocks into PLC
AGWriteDB(dbNumber int, start int, size int, buffer []byte) (err error)
//Read Merkers area from PLC
AGReadMB(start int, size int, buffer []byte) (err error)
//Write Merkers from into PLC
AGWriteMB(start int, size int, buffer []byte) (err error)
//Read IPI from PLC
AGReadEB(start int, size int, buffer []byte) (err error)
//Write IPI into PLC
AGWriteEB(start int, size int, buffer []byte) (err error)
//Read IPU from PLC
AGReadAB(start int, size int, buffer []byte) (err error)
//Write IPU into PLC
AGWriteAB(start int, size int, buffer []byte) (err error)
//Read timer from PLC
AGReadTM(start int, size int, buffer []byte) (err error)
//Write timer into PLC
AGWriteTM(start int, size int, buffer []byte) (err error)
//Read counter from PLC
AGReadCT(start int, size int, buffer []byte) (err error)
//Write counter into PLC
AGWriteCT(start int, size int, buffer []byte) (err error)
//multi read area
AGReadMulti(dataItems []S7DataItem, itemsCount int) (err error)
//multi write area
AGWriteMulti(dataItems []S7DataItem, itemsCount int) (err error)
/*block*/
DBFill(dbnumber int, fillchar int) error
DBGet(dbnumber int, usrdata []byte, size int) error
//general read function with S7 sytax
Read(variable string, buffer []byte) (value interface{}, err error)
//Get block infor in AG area, refer an S7BlockInfor pointer
GetAgBlockInfo(blocktype int, blocknum int) (info S7BlockInfo, err error)
/***************end API AG***************/
/***************start API PG (Programmiergerät)***************/
/*control*/
//Hotstart PLC, Puts the CPU in RUN mode performing an HOT START.
PLCHotStart() error
//Cold start PLC, change CPU into runmode performing and COLD START
PLCColdStart() error
//change CPU to stop mode
PLCStop() error
//return CPU status: running/stopped
PLCGetStatus() (status int, err error)
/*directory*/
//list all blocks in PLC, return a Blockslist which contains list of OB, DB, ...
PGListBlocks() (list S7BlocksList, err error)
/*security*/
//set the session password for PLC to meet its security level
SetSessionPassword(password string) error
//clear the password set for current session
ClearSessionPassword() error
//return the CPU protection level info, refer to: §33.19 of "System Software for S7-300/400 System and Standard Functions"
//return S7Protection and its properties.
GetProtection() (protection S7Protection, err error)
/*system information*/
//get CPU order code, return S7OrderCode
GetOrderCode() (info S7OrderCode, err error)
//get CPU info, return S7CpuInfo and its properties
GetCPUInfo() (info S7CpuInfo, err error)
//get CP info, return S7CpInfo and its properties
GetCPInfo() (info S7CpInfo, err error)
/*datetime*/
//read clock on PLC, return a time
PGClockRead(datetime time.Time) error
//write clock to PLC with datetime input
PGClockWrite() (dt time.Time, err error)
/***************end API AG***************/
}