fixed a typeo bug where LocoNet Receive only worked after a transmit
Browse files Browse the repository at this point in the history
added another example sketch: LocoNetHwCommsTest
  • Loading branch information
kiwi64ajs committed Oct 19, 2021
1 parent 6e8d983 commit 46ad1cc
Show file tree
Hide file tree
Showing 3 changed files with 138 additions and 2 deletions.
136 changes: 136 additions & 0 deletions examples/LocoNetHwCommsTest/LocoNetHwCommsTest.ino
Original file line number Diff line number Diff line change
@@ -0,0 +1,136 @@
#include <LocoNet.h>

// LocoNet Hardware Communication Test sketch
//
// This sketch can be used to test the normal operation of the LocoNet Comms Hardware by printing out any received LocoNet messages
// and sending a Report Sensor message with an incrementing address every second and prints the send message status

// Define your LocoNet TX Pin below
#define TX_PIN 7

// Uncomment the line below to enable periodicall sending an incrementing LocoNet Sensor Message
//#define SEND_TEST_MESSAGE_PERIOD_MS 1000

static lnMsg *LnPacket;

void setup()
{
Serial.begin(115200);

while (!Serial); // Wait for the USB Serial Port to initialise

Serial.println("LocoNet Hardware Communication Test");

// First initialize the LocoNet interface, specifying the TX Pin
LocoNet.init(TX_PIN);
}

boolean isTime(unsigned long *timeMark, unsigned long timeInterval)
{
unsigned long timeNow = millis();
if ( timeNow - *timeMark >= timeInterval) {
*timeMark = timeNow;
return true;
}
return false;
}

#ifdef SEND_TEST_MESSAGE_PERIOD_MS
unsigned long lastTxTime = 0;
uint16_t lastSensorAddr = 0;
#endif

void loop()
{
// Check for any received LocoNet packets
LnPacket = LocoNet.receive() ;
if( LnPacket )
{
// Get the length of the received packet
uint8_t msgLen = getLnMsgSize( LnPacket ) ;
Serial.print("\nRx: ");
for (uint8_t x = 0; x < msgLen; x++)
{
uint8_t val = LnPacket->data[x];
// Print a leading 0 if less than 16 to make 2 HEX digits
if (val < 16)
Serial.print('0');

Serial.print(val, HEX);
Serial.print(' ');
}

// If this packet was not a Switch or Sensor Message then print a new line
if (!LocoNet.processSwitchSensorMessage(LnPacket))
Serial.println();
}

#ifdef SEND_TEST_MESSAGE_PERIOD_MS
// Send a Report Sensor Message every second with an incrementing address
if( isTime(&lastTxTime, 1000))
{
if(++lastSensorAddr >= 1000)
lastSensorAddr = 0;

LN_STATUS lnStatus = LocoNet.reportSensor(lastSensorAddr, 1);

Serial.print("Tx: Sensor: ");
Serial.print(lastSensorAddr);
Serial.print(" Status: ");
Serial.println(LocoNet.getStatusStr(lnStatus));
}
#endif
}

// This call-back function is called from LocoNet.processSwitchSensorMessage
// for all Sensor messages
void notifySensor( uint16_t Address, uint8_t State ) {
Serial.print("Sensor: ");
Serial.print(Address, DEC);
Serial.print(" - ");
Serial.println( State ? "Active" : "Inactive" );
}

// This call-back function is called from LocoNet.processSwitchSensorMessage
// for all Switch Request messages
void notifySwitchRequest( uint16_t Address, uint8_t Output, uint8_t Direction ) {
Serial.print("Switch Request: ");
Serial.print(Address, DEC);
Serial.print(':');
Serial.print(Direction ? "Closed" : "Thrown");
Serial.print(" - ");
Serial.println(Output ? "On" : "Off");
}

// This call-back function is called from LocoNet.processSwitchSensorMessage
// for all Switch Output Report messages
void notifySwitchOutputsReport( uint16_t Address, uint8_t ClosedOutput, uint8_t ThrownOutput) {
Serial.print("Switch Outputs Report: ");
Serial.print(Address, DEC);
Serial.print(": Closed - ");
Serial.print(ClosedOutput ? "On" : "Off");
Serial.print(": Thrown - ");
Serial.println(ThrownOutput ? "On" : "Off");
}

// This call-back function is called from LocoNet.processSwitchSensorMessage
// for all Switch Sensor Report messages
void notifySwitchReport( uint16_t Address, uint8_t State, uint8_t Sensor ) {
Serial.print("Switch Sensor Report: ");
Serial.print(Address, DEC);
Serial.print(':');
Serial.print(Sensor ? "Switch" : "Aux");
Serial.print(" - ");
Serial.println( State ? "Active" : "Inactive" );
}

// This call-back function is called from LocoNet.processSwitchSensorMessage
// for all Switch State messages
void notifySwitchState( uint16_t Address, uint8_t Output, uint8_t Direction ) {
Serial.print("Switch State: ");
Serial.print(Address, DEC);
Serial.print(':');
Serial.print(Direction ? "Closed" : "Thrown");
Serial.print(" - ");
Serial.println(Output ? "On" : "Off");
}
2 changes: 1 addition & 1 deletion library.properties
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
name=LocoNet
version=1.1.7
version=1.1.8
author=Alex Shepherd, John Plocher, Damian Philipp, Tom Knox, Hans Tanner, Björn Rennfanz
maintainer=Alex Shepherd <[email protected]>
sentence=Enables Digitrax LocoNet Communication
Expand Down
2 changes: 1 addition & 1 deletion utility/ln_sw_uart.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -496,7 +496,7 @@ void initLocoNetHardware(LnBuf * RxBuffer)
//Clear StartBit Interrupt flag
LN_CLEAR_START_BIT_FLAG();
//Enable StartBit Interrupt
LN_CLEAR_START_BIT_FLAG();
LN_ENABLE_START_BIT_INTERRUPT();

//Set rising edge for StartBit if signal is inverted
# ifdef LN_SW_UART_RX_INVERTED
Expand Down

0 comments on commit 46ad1cc