39 changes: 28 additions & 11 deletions resources/hpxml-measures/workflow/tests/hpxml_translator_test.rb
Original file line number Diff line number Diff line change
Expand Up @@ -541,12 +541,10 @@ def _verify_outputs(rundir, hpxml_path, results, hpxml)
next if message.include? 'Pump nominal power or motor efficiency is set to 0'
next if message.include? 'volume flow rate per watt of rated total cooling capacity is out of range'
next if message.include? 'volume flow rate per watt of rated total heating capacity is out of range'
next if message.include? 'Timestep: Requested number'
next if message.include? 'The Standard Ratings is calculated for'
next if message.include?('WetBulb not converged after') && message.include?('iterations(PsyTwbFnTdbWPb)')
next if message.include? 'Inside surface heat balance did not converge with Max Temp Difference'
next if message.include? 'Inside surface heat balance convergence problem continues'
next if message.include? 'Missing temperature setpoint for LeavingSetpointModulated mode' # These warnings are fine, simulation continues with assigning plant loop setpoint to boiler, which is the expected one
next if message.include?('Glycol: Temperature') && message.include?('out of range (too low) for fluid')
next if message.include?('Glycol: Temperature') && message.include?('out of range (too high) for fluid')
next if message.include? 'Plant loop exceeding upper temperature limit'
Expand All @@ -563,10 +561,8 @@ def _verify_outputs(rundir, hpxml_path, results, hpxml)
next if message.include? 'Iteration limit exceeded in calculating sensible part-load ratio error continues'
next if message.include?('setupIHGOutputs: Output variables=Zone Other Equipment') && message.include?('are not available.')
next if message.include?('setupIHGOutputs: Output variables=Space Other Equipment') && message.include?('are not available')
next if message.include? 'Actual air mass flow rate is smaller than 25% of water-to-air heat pump coil rated air flow rate.' # FUTURE: Remove this when https://github.com/NREL/EnergyPlus/issues/9125 is resolved
next if message.include? 'DetailedSkyDiffuseModeling is chosen but not needed as either the shading transmittance for shading devices does not change throughout the year'
next if message.include? 'View factors not complete'
next if message.include?('CheckSimpleWAHPRatedCurvesOutputs') && message.include?('WaterToAirHeatPump:EquationFit') # FUTURE: Check these

# HPWHs
if hpxml.water_heating_systems.select { |wh| wh.water_heater_type == HPXML::WaterHeaterTypeHeatPump }.size > 0
Expand All @@ -577,6 +573,7 @@ def _verify_outputs(rundir, hpxml_path, results, hpxml)
next if message.include? 'Enthalpy out of range (PsyTsatFnHPb)'
next if message.include?('CheckWarmupConvergence: Loads Initialization') && message.include?('did not converge after 25 warmup days')
end
# HPWHs outside
if hpxml.water_heating_systems.select { |wh| wh.water_heater_type == HPXML::WaterHeaterTypeHeatPump && wh.location == HPXML::LocationOtherExterior }.size > 0
next if message.include? 'Water heater tank set point temperature is greater than or equal to the cut-in temperature of the heat pump water heater.'
end
Expand All @@ -586,8 +583,13 @@ def _verify_outputs(rundir, hpxml_path, results, hpxml)
end
# HP defrost curves
if hpxml.heat_pumps.select { |hp| [HPXML::HVACTypeHeatPumpAirToAir, HPXML::HVACTypeHeatPumpMiniSplit, HPXML::HVACTypeHeatPumpPTHP, HPXML::HVACTypeHeatPumpRoom].include? hp.heat_pump_type }.size > 0
next if message.include?('GetDXCoils: Coil:Heating:DX') && message.include?('curve values')
next if message.include?('GetDXCoils: Coil:Heating:DX') && message.include?('curve values') && message.include?('Defrost Energy Input Ratio Function of Temperature Curve')
end
# variable system SHR adjustment
if (hpxml.heat_pumps + hpxml.cooling_systems).select { |hp| hp.compressor_type == HPXML::HVACCompressorTypeVariableSpeed }.size > 0
next if message.include?('CalcCBF: SHR adjusted to achieve valid outlet air properties and the simulation continues.')
end
# Evaporative coolers
if hpxml.cooling_systems.select { |c| c.cooling_system_type == HPXML::HVACTypeEvaporativeCooler }.size > 0
# Evap cooler model is not really using Controller:MechanicalVentilation object, so these warnings of ignoring some features are fine.
# OS requires a Controller:MechanicalVentilation to be attached to the oa controller, however it's not required by E+.
Expand All @@ -600,19 +602,37 @@ def _verify_outputs(rundir, hpxml_path, results, hpxml)
# input "Autosize" for Fixed Minimum Air Flow Rate is added by OS translation, now set it to 0 to skip potential sizing process, though no way to prevent this warning.
next if message.include? 'Since Zone Minimum Air Flow Input Method = CONSTANT, input for Fixed Minimum Air Flow Rate will be ignored'
end
# Fan coil distribution
if hpxml.hvac_distributions.select { |d| d.air_type.to_s == HPXML::AirTypeFanCoil }.size > 0
next if message.include? 'In calculating the design coil UA for Coil:Cooling:Water' # Warning for unused cooling coil for fan coil
end
if hpxml_path.include?('ground-to-air-heat-pump-cooling-only.xml') || hpxml_path.include?('ground-to-air-heat-pump-heating-only.xml')
next if message.include? 'COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT' # heating capacity is > 20% different than cooling capacity; safe to ignore
# Boilers
if hpxml.heating_systems.select{ |h| h.heating_system_type == HPXML::HVACTypeBoiler }.size > 0
next if message.include? 'Missing temperature setpoint for LeavingSetpointModulated mode' # These warnings are fine, simulation continues with assigning plant loop setpoint to boiler, which is the expected one
end
# GSHPs
if hpxml.heat_pumps.select{ |hp| hp.heat_pump_type == HPXML::HVACTypeHeatPumpGroundToAir }.size > 0
next if message.include?('CheckSimpleWAHPRatedCurvesOutputs') && message.include?('WaterToAirHeatPump:EquationFit') # FUTURE: Check these
next if message.include? 'Actual air mass flow rate is smaller than 25% of water-to-air heat pump coil rated air flow rate.' # FUTURE: Remove this when https://github.com/NREL/EnergyPlus/issues/9125 is resolved
end
# GSHPs with only heating or cooling
if hpxml.heat_pumps.select{ |hp| hp.heat_pump_type == HPXML::HVACTypeHeatPumpGroundToAir && (hp.fraction_heat_load_served == 0 || hp.fraction_cool_load_served == 0) }.size > 0
next if message.include? 'heating capacity is disproportionate (> 20% different) to total cooling capacity' # safe to ignore
end
# Solar thermal systems
if hpxml.solar_thermal_systems.size > 0
next if message.include? 'Supply Side is storing excess heat the majority of the time.'
end
# Unavailability periods
if !hpxml.header.unavailable_periods.empty?
next if message.include? 'Target water temperature is greater than the hot water temperature'
next if message.include? 'Target water temperature should be less than or equal to the hot water temperature'
end
# Simulation w/ timesteps longer than 15-minutes
timestep = hpxml.header.timestep.nil? ? 60 : hpxml.header.timestep
if timestep > 15
next if message.include?('Timestep: Requested number') && message.include?('is less than the suggested minimum')
end

flunk "Unexpected eplusout.err message found for #{File.basename(hpxml_path)}: #{message}"
end
Expand Down Expand Up @@ -648,10 +668,7 @@ def _verify_outputs(rundir, hpxml_path, results, hpxml)
assert_equal(0, num_invalid_output_variables)

# Timestep
timestep = hpxml.header.timestep
if timestep.nil?
timestep = 60
end
timestep = hpxml.header.timestep.nil? ? 60 : hpxml.header.timestep
query = 'SELECT NumTimestepsPerHour FROM Simulations'
sql_value = sqlFile.execAndReturnFirstDouble(query).get
assert_equal(60 / timestep, sql_value)
Expand Down

0 comments on commit 8c77c73

Please sign in to comment.