dbus-modbus-eastron

Integrate Eastron grid meters into Victron Energies Venus OS

Purpose

With the scripts in this repo it should be easy possible to install, uninstall, restart a service that connects Eastron grid meters to the VenusOS and GX devices from Victron.

Installation

Get the code

Just grab a copy of the main branch and copy them to a folder under /data/ e.g. /dbus-modbus-eastron. After that call the install.sh script.

The following script should do everything for you:

wget https://github.com/telekatz/venus.dbus-modbus-eastron/archive/refs/heads/main.zip
unzip main.zip "venus.dbus-modbus-eastron-main/*" -d /data
mv /data/venus.dbus-modbus-eastron-main /data/dbus-modbus-eastron
chmod a+x /data/dbus-modbus-eastron/install.sh
/data/dbus-modbus-eastron/install.sh
rm main.zip

Before installing a new version, uninstall the installed version:

/data/dbus-modbus-eastron/uninstall.sh

Settings

The following settings are available in the device settings menu inside Venus OS:

Config value Explanation
Role Valid values Grid meter, PV inverter, Generator or AC load: mode of operation for the energy meter.
Position Only for PV inverter. Valid values AC input 1, AC input 2 or AC output: Position where the device is connected.
Phase Only for single phase grid meters. Valid values L1, L2 or L3: represents the phase where the device is connected.
Refresh Rate Update rate of power measurement.
Energy Counter Source Method of calculating total imported and exported energy:
Device Value: Raw values from the energy meter.
Balancing: Balancing calculation of imported and exported energy.
Import - Export: Difference between imported and exported energy.